National Instruments 6008 用户手册

下载
页码 27
© National Instruments Corporation
11
NI USB-6008/6009 User Guide and Specifications
Signal Descriptions
Table 5 describes the signals available on the I/O connectors.
Table 5.  Signal Descriptions
Signal Name
Reference
Direction
Description
GND
Ground—The reference point for the 
single-ended AI measurements, bias 
current return point for differential mode 
measurements, AO voltages, digital 
signals at the I/O connector, 
+5 VDC 
supply, and the 
+2.5 VDC reference.
AI <0..7>
Varies
Input
Analog Input Channels 0 to 7—For 
single-ended measurements, each signal is 
an analog input voltage channel. For 
differential measurements, AI 0 and AI 4 
are the positive and negative inputs of 
differential analog input channel 0. 
The following signal pairs also form 
differential input channels: 
<AI 1, AI 5>, <AI 2, AI 6>, and 
<AI 3, AI 7>.
AO 0
GND
Output
Analog Channel 0 Output—Supplies the 
voltage output of AO channel 0. 
AO 1
GND
Output
Analog Channel 1 Output—Supplies the 
voltage output of AO channel 1.
P1.<0..3>
P0.<0..7>
GND
Input or
Output
Digital I/O Signals—You can 
individually configure each signal as an 
input or output. 
+2.5 V
GND
Output
+2.5 V External Reference—Provides a 
reference for wrap-back testing.
+5 V
GND
Output
+5 V Power Source—Provides +5 V 
power up to 200 mA.
PFI 0
GND
Input 
PFI 0—This pin is configurable as either a 
digital trigger or an event counter input.