Connection/Installation
92
 
Ñ
Microphone unit
1) Check the installation position of the 
microphone (accessory 4).
2) Clean the installation surface.
3) Remove the separator of the microphone 
(accessory 4), and stick the microphone to 
the place shown below.
4) Wire the microphone cable up to the unit 
with it secured at several positions using tape 
or other desired method.
5) Adjust the direction of the microphone 
(accessory 4) to the driver.
4
Fix a cable with a commercial item of tape.
 
Ñ
Removing the trim plate 
(DNX994S)
1) Engage the catch pins on the extraction key 
(accessory 5) and remove the two locks on 
the lower level. 
Lower the trim plate (accessory 0) and pull it 
forward as shown in the figure.
5
0
Lock
Catch
NOTE
•  The trim plate can be removed from the top side 
in the same manner.
2) When the lower level is removed, remove the 
upper two locations.
 
Ñ
Removing the unit (DNX994S)
1) Remove the trim plate by referring to step 1 in 
"Removing the trim plate".
2) Insert the two extraction key (accessory 5) 
deeply into the slots on each side, as shown.
5
3) Lower the extraction key toward the bottom, 
and pull out the unit halfway while pressing 
towards the inside.
NOTE
•  Be careful to avoid injury from the catch pins on 
the extraction key.
4) Pull the unit all the way out with your hands, 
being careful not to drop it.