Redline Communications Inc. AN80IC 用户手册

下载
页码 94
 
Red
CONNEX
™   
 
User
 
 
AN-80i
 
Manual
 
 
70-00072-01-05-DRAFT 
Proprietary Redline Communications © 2008
 
Page 69 of 94 
January 22, 2008 
Table 27: CLI - set 
PTP PMP Parameter/Description 
 
√ 
congid
: Connection's group ID. 
 <id>   
 - [id number] 
 <gid>   
- <gid> 
 
√ 
conlid
: Connection's Link ID. 
 <id>   
 - [id number] 
 <lid>   
- <lid> 
 
√ 
conpri
: Connection priority. 
 <id>   
 - [id number] 
 <pri>   
- <VLAN priority> 
 
√ 
convid
: Connection VLAN ID. 
 <id>   
 - [id number] 
 <vid>   
- <VLAN ID> 
 
√ 
conviden
: Connection VLAN enable. 
 <id>   
 - [id number] 
 <mode> 
 
- <on/off> 
√ 
 
dfsaction
: Select the mode of operation for DFS. The system set to master-
mode monitors for interference from radar devices and other equipment using 
the same channel frequency. When interference is detected, the system 
automatically takes the action selected using the drop-down menu: 
 <action> 
 - [none=0 | txoff=1 | chgfreq=2] 
None
: The DFS function is disabled. 
Tx Off
: Transmission is immediately disabled when radar signals are 
detected. This action is recorded in the message log and an SNMP trap 
message is sent (if SNMP enabled). 
Chg Freq
: Relocate transmission to an alternative frequency immediately 
when radar signals are detected. This action is recorded in the message 
log and a trap message is sent (if SNMP enabled). 
 
√ 
dlqos
: Downlink QoS. 
 <id>   
 - [id number] 
 <qos>   
- <QoS> 
 
√ 
dlrate
: Downlink rate. 
 <id>   
 - [id number] 
 <rate>   
- <rate> 
 
 
dst
: Enter the actual length of the path that the wave travels in order to 
establish the link. Units are defined by dstmu setting. 
This value is used to calculate the transmission-to-response interval and 
disregard reflections of the transmitted signal. Used only if dstmod is set to 
'manual'. 
 
 
dstmode
: Select the mode for determining the distance of the wireless link. 
 
auto
: Distance is calculated automatically by the AN-80i. 
 
manual
: Operator enters link distance. 
 
 
dstmu
: Select the measurement unit for the link length (dstmode). 
 
mile
 - dstmode units are miles 
 
km
 - dstmode units are kilometers