5.3.13 Set 
Use the set command to view and/or change a parameter. 
View a parameter: 
set [field] <Enter> 
Change a parameter: 
set [field] [value] <Enter> 
Table 27: CLI - set 
PTP PMP Parameter/Description 
 
√ 
activekey
: Current active options key. 
 <active_idx>   - [ 0 | 1] 
√ 
 
adaptmod
: Enable or disable the adaptive modulation function. 
 
off
 - Disable 
 
on
 - Enable 
When enabled, the AN-80i will automatically change the modulation to the 
highest setting that can sustain a packet error rate lower than 1x10e-6. If the 
packet error rate exceeds 1x10e-6, the system automatically steps down 
modulation/code rate (i.e., from 16 QAM 3/4 to 16 QAM 1/2 ) to maintain the 
wireless link quality. 
√ 
 
antgain
: Enter value for antenna gain (dBi). 
When DFS is enabled, it is important that the Antenna Gain setting matches the 
true antenna gain. If the antenna gain is set higher incorrectly, the AN-80i is 
less sensitive to detecting interference, and is not operating in compliance with 
the UK/ETSI standard. 
 
 
atpc
: Enable or disable the ATPC function. Both AN-80i units monitor Rx signal 
and automatically adjust the Tx level of the transmitting system to optimize 
system performance. The ATPC feature must be enabled on both ends of the 
link. 
 
off
 - Disable 
 
on
 - Enable  
This mode can be changed only if allowed by the options key. If the options key 
does not allow changes: 1) value is specified by the options key, 2) executing a 
set command for this field will generate an error message. 
 
 
autoscan
: Enable or disable the Autoscan function. 
 
off
 - Disable 
 
on
 - Enable  
When enabled, the PTP Subscriber (system mode) AN-80i automatically scans 
available channels to locate the current operating frequency of the PTP Sector 
Controller system. Executing a set command this field on a PTP Sector 
Controller will generate an error message. 
 
√ 
bsporten
: Sector controller Ethernet port enable. 
 <id>   
 - [id number] 
 <mode> 
 
- <on/off> 
 
 
buzzer
: Enable or disable the audible alignment buzzer. 
 
off
 - Disable 
 
on
 - Enable 
When enabled, the rate of the tone is proportional to the receive signal strength 
(faster = stronger signal). 
 
 
chwidth