7 Installing a pRRU3901 
 
Issue 08 (2016-05-30) 
Huawei Proprietary and Confidential         
Copyright © Huawei Technologies Co., Ltd. 
102 
 
Prerequisites 
 
The Ethernet cable must be of Category 5e (enhanced) or higher. In addition, its 
cross-sectional area must be 24 AWG or larger and frame spread rating must be CM or 
higher. 
 
The Ethernet cables can be straight-through cables or crossover cables. 
 
With the internal PoE module providing power, the maximum length of an Ethernet 
cable is 100 m. With the Extender, the distance of the pRRU3901 and RHUB can be 
extended by the Extender up to a total distance of 200 m. 
 
Ethernet cables are not delivered, and they must be prepared onsite. You need to use a 
network cable tester to test the Ethernet cable connection. 
Context 
The Ethernet cable has the following functions: 
 
Provides power supply for the pRRU3901 when the cable connects the CPRI_E0 port on 
the pRRU3901 to the RHUB. 
 
Transmits CPRI signals between an RHUB and a pRRU3901. 
 
Provides Wi-Fi services for the pRRU3901 when the cable connects the GE port on the 
pRRU3901 with three transmission ports to the AC. 
Using the CPRI_E1 port on the pRRU3901 has the same Ethernet cable connection to the 
RHUB as using the CPRI_E0 port. The following section describes the connection using the 
CPRI_E0 port. 
For details about the cable connections in the different scenarios, see 7.5.3 Cable Connections 
(Indoor) and 7.5.4 Cable Connections (Outdoor). The Ethernet cable connections between 
RHUB and pRRUs are the same. The following section describes the connections between 
RHUB-Extender-pRRU3901 as an example. 
In the outdoor scenario, PoE surge protector is needed to provide surge protection for the 
Ethernet ports. For details about the installation of PoE surge protector, see 12 (Optional) 
Installing the PoE Surge Protector and Cables. 
Procedure 
Step 1  Make the Ethernet cables. 
1. 
Assemble an RJ45 connector and an Ethernet cable by following instructions in 
Assembling the Unshielded RJ45 Connector and the Ethernet Cable of Installation 
Reference
 
Follow pin assignment instructions described in section Ethernet Cable in DBS3900 LampSite Hardware 
Description
 to assemble the unshielded RJ45 connector and the Ethernet cable. Otherwise, the 
transmission signal quality deteriorates and CPRI links may be disconnected. 
2. 
Check whether the made RJ45 connector is qualified by following instructions in 
Checking the Appearance of Metal Contact Strips. 
3. 
To complete the assembly of the other end, repeat 
. 
4. 
Check whether the touch points on the connectors at both ends are normally conducted 
and well contacted and whether the connections are correct by following instructions in 
Testing the Connection of Assembled Cables of Installation Reference
Step 2  Install an Ethernet cable between an RHUB and a pRRU3901.