Huawei Technologies Co. Ltd PRU11WIFI 用户手册

下载
页码 303
DBS3900 LampSite 
Installation Guide 
7 Installing a pRRU3901 
 
Issue 08 (2016-05-30) 
Huawei Proprietary and Confidential         
Copyright © Huawei Technologies Co., Ltd. 
103 
 
1. 
Remove the dustproof cap of the CPRI_E0 port on the pRRU3901. 
2. 
Connect the RJ45 connector at one end of the Ethernet cable to the CPRI_E0 port on the 
pRRU3901 panel. 
3. 
Optional: 
Connect the RJ45 connector at the other end of the Ethernet cable to the 
output port of the Extender. Then, connect the RJ45 connector at one end of another 
Ethernet cable to the input port of the Extender. 
4. 
Connect the RJ45 connector at the other end of the Ethernet cable to any port ranging 
from CPRI_E0 to CPRI_E7 on the RHUB panel based on the engineering design, as 
shown in Figure 7-40. 
Figure 7-40
 Installing an Ethernet cable 
 
(1) Ethernet cable  (2) GE port on the pRRU3901 
(3) CPRI_E0 port on the pRRU3901 
 
The pRRU3901 can have two transmission ports plus one PWR port or three transmission ports (plus 
one PWR port or no PWR port), requiring the same installation operations. This section uses the 
pRRU3901 with three transmission ports no PWR port as an example. 
 
Step 3  Optional: Install the Ethernet cable between the pRRU3901 and the AC. This operation is 
required when the pRRU3901 with three transmission ports is configured with a Wi-Fi 
daughter board. 
1. 
Remove the dustproof cap of the GE port on the pRRU3901. 
2. 
Connect the RJ45 connector at one end of the Ethernet cable to the GE port on the 
pRRU3901 panel. 
3. 
Connect the RJ45 connector at the other end of the Ethernet cable to the transmission 
port of the AC based on the engineering design, as shown in Figure 7-40. 
----End 
Follow-up Procedure 
1. 
Route the cable, and then use a cable tie to bind the cable. For details, see 7.5.1 
Requirements for Cable Layout. 
2. 
Label the installed cable. For details, see section 15.4 Attaching an L-Shaped Label.