Fault-finding
Symptom
Cause
Action
RMP60 fails to switch off
Incorrect switch off method
Check configuration and alter
configured.
as required.
No RMI ‘start/stop’ signal
Check for green start LED
(applicable only in radio off,
Check wiring.
mode, but not applicable in
Heidenhain mode).
Probe in time out and placed
Review use of time out mode.
in tool magazine and is being
Increase  spring  force.
triggered by movement.
Malfunctioning shank switch
Check switch operation.
(shank switch mode only).
Incorrect spin speed
Check spin speed.
(spin turn on only).
RMP60 status LED’s
Dead batteries.
Change batteries.
continuous red
Poor battery life
Radio link failure – RMP out
Check position of RMI, see
of RMI range.
performance envelope.
RMI power has been removed.
Check power to RMI, leave
RMI powered all the time.
Local radio interference.
Identify and move.
Probe crash
Inspection probe using
Review program
tool-setting probe signals.