Renishaw plc RMP60 用户手册

下载
页码 42
34
Symptom
Cause
Action
RMI error LED lit during
Probe timed out
Change setting.
probing cycle (continued)
Review turn off method
Probe out of range
Check position of RMI, see
performance envelope.
RMI error LED illuminated
Probe not switched on.
Check configuration and alter
during intended probe cycle
as required
Probe out of range
Check position of RMI, see
performance envelope.
All RMI LED’s flashing
Wiring fault.
Check  wiring
Output over current.
Check wiring, turn power to
RMI off and on again to reset
RMI low battery led lit
Low  batteries.
Change  batteries  soon
Reduced range
Local radio interference
Identify and move
Poor repeatability
Probing occurs within
Review probe software
machine’s acceleration/
deceleration zones.
Probe feedrate too high
Check feedrate and correct,
test at different speeds.
Temperature variation
Minimise temperature .
change.
Calibrate more frequently.
Calibrate just before use.
Slack in machine tool
Perform health check on
machine.
Fault-finding