Deister Electronic GmbH TSU200 用户手册

下载
页码 24
 8.3.2  Basic Setup
Enable RS485 termination
If this check box is selected, the internal RS485 termination of the reader is switched on.
This function is permanently activated in the TSU 200!
read mode
This parameter defines, if the reader expects only one tag in the antenna field or if there
may be more tags within the antenna field. In case there are more tags, the reader has to
execute an anti collision algorithm. It is also possible to configure the reader to “single
shot” mode in which the read signaling for the same transponder is only done once or
after a timeout defined by parameter “tag timeout”.
Anti collision:
Operating mode in case there is more than one tag in the field
single shot:
Operating mode for reading tag data, in case there is only one tag
in the field. The tag data will be transmitted again after the time
specified in “tag timeout”.
Beim TSU 200 bleibt anti collision aktiviert!
tag timeout / ms (for read mode “single shot” only)
This value defines the interval (timeout) in milliseconds between transmissions of a tag in
"single shot" mode. After expiration of this interval it is signaled that the tag will be read
again. In the TSU 200 this value remains set to 65535.
RF power / dBm
This value defines the radiated power of the antenna in dBm. The maximum output power
of the antenna is 32 dBm.
Zulassung_wi_en_ts_tsu-200_pro_v140205_te_bf
19