Rosslare Enterprises Ltd AYCF6X 用户手册

下载
页码 66
Installation 
14 
AYC-F/G/M60 Series Installation and Programming Manual 
6.
  Insert the unit’s cable wire into the cable hole and wire the unit 
as described in Section 
7.
  Screw the back cover to its mounting location. 
8.
  Carefully re-attach the front cover of the unit. 
9.
  Secure the front cover by using the supplied security Torx screw. 
A Torx security screw tool is provided to tighten the security Torx 
screw. 
3.2
 
Wiring 
The unit is supplied with a 6-conductor 56-cm (22-in.) pigtail with 
exposed wires coated with solder. 
3.2.1
 
Wiring the Unit as a Reader 
If you connect the unit to a standard access control unit, it 
automatically functions as a reader. 
To connect the unit as a reader (to a controller): 
1.
  Select the appropriate connections according to Table 1. 
Table 1: Wiring the Reader to the Controller 
Wire Color  Function 
Black/Shield 
Ground (+) 
Red 
Vin (-) 
Green 
Data 0/Data (D0) 
White 
Data 1/Clock (D1) 
Brown 
LED control 
Purple 
Tamper 
2.
  Prepare the controller cable by cutting the cable jacket back 3.2 
cm (1¼”) and strip the wire 1.3 cm (½”). 
3.
  Splice the reader’s pigtail wires to the corresponding controller 
wires and cover each joint with insulating tape. 
4.
  If the tamper output is being utilized, connect the purple wire to 
the correct input on the controller.