5.
Trim and cover all conductors that are not used.
•
The individual wires extending from the reader are color-coded
according to the required Wiegand standard.
•
When using a separate power supply for the reader, this supply and
the controller’s power supply must have a common ground. A linear
power supply is recommended.
power supply is recommended.
•
Attach the cable shield wire on the reader to an earth ground (best),
or to a signal ground connection at the panel or power supply end of
the cable. This configuration is best for shielding the reader cable from
external interference.
external interference.
3.2.2
Wiring the Unit as a Controller
If you connect the unit to a Rosslare PS-x25x secured power supply, it
automatically functions as a controller.
To connect the unit as a controller:
1.
Select the appropriate connections according to Table 2.
Table 2: Wiring the Unit as a Controller
Controller Wire Color Function
Note
-
Red
+DC Input
Wired to the PS-x25x
+
Black
Ground
Wired to the PS-x25x
C 1
White
Communication
Wired to the PS-x25x
C 2
Green
Communication
Wired to the PS-x25x
AUX. IN
Brown
Auxiliary Input
Wired to input
N/A
Purple
Not in use
N/A
Attach the cable shield wire on the unit to an earth ground (best).
You can also attach it to a signal ground connection at the panel or
power supply end of the cable. This configuration is best for
shielding the controller cable from external interference.
power supply end of the cable. This configuration is best for
shielding the controller cable from external interference.
2.
Prepare the PS-x25x secured power supply’s cable by cutting the
cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
3.
Splice the controller pigtail wires to the corresponding PS-x25x
secured power supply’s wires and cover each joint with insulating