Andrew Wireless Innovations Group RPT-MR701 用户手册

下载
页码 76
User’s manual for Repeater MR801B Power
M0067A0A.doc
Id.-No 151111
Page 25
02-JUNE-99
All alarms can be checked by typing the ‘STATUS HIST’ command. Minor alarms with no
influence on the system can be cancelled by typing the ‘ALARMACKN’ command, e.g. ALC
active, VSWR or door open. The following print screen illustrates a possible ‘STATUS
HIST’ report
figure 3-3 Status hist report
In case a hardware failure is detected the concerning hardware module has to be replaced. An
alarm can be acknowledged manually by software command. If all alarms have been
acknowledged the summary error LEDs are set back to green indication.
In case of mains power failure all data of the STATUS HIST list are lost.
The alarm can also be sent to the OMC.
If monitored via a modem automatic dialling will generate a summary alarm message. The
operator can acknowledge the alarm message by a simple ring back and after that he is able to
request a detailed status report.
The following list comprises all available alarms in the Repeater. These alarms may occur in
the STATUS HIST list.