User’s manual for Repeater MR801B Power
M0067A0A.doc
Id.-No 151111
Page 26
02-JUNE-99
NO.
ALARM NAME
ALARM ACTIVE STATUS
1
AMPLIFIER BIAS
FAILURE
2
POWER SUPPLY 8 V
FAILURE
3
POWER SUPPLY 12 V
FAILURE
4
MAINS
FAILURE
5
SYNTH
FAILURE
6
DOOR
OPEN
(7)
VSWR
ALARM
8
ALC
FAILURE
9
LITHIUM BATTERY VOLTAGE
LOW
10
OVERTEMP
11
INVALID LOGIN ATTEMPT
12
I2C BUS
FAILURE
(13*)
EXT. ALARM 1
FAILURE
(14*)
EXT. ALARM 2
FAILURE
(15*)
EXT. ALARM 3
FAILURE
(16*)
EXT. ALARM 4
FAILURE
(17**)
EXT. BATTERY
OVERTEMP.
Alarm default settings changeable by software instruction SET ALIAS.
** 
This alarm may be activated together with the external alarms, for instance UPS
temperature
(...)
Optional alarms
table 3-4 List of all available alarms
3.4.1 Handling of alarms
As soon as the software recognizes a valid alarm, a message is transmitted to the terminal.
In remote mode via modem, the first of two stored telephone numbers will be dialled. In case
a connection cannot be established the second telephone number will be dialled. If this should
be unsuccessful as well, the call will be repeated after a pre-set delay. The delay time can be
set by software.
If the connection can be established the alarm message will be sent including date, time and
Repeater Id.-number.
In remote mode the alarm can be acknowledged by simply ringing back and typing
ALARMACKN.