High Power HPC-500-H12S 用户手册
Switching Power Supply Specifications
Page 10
10. MTBF
The MTBF of the power should be 50,000 hours min.
11. Burn-In
11.1 Input Voltage
Applying 220Vac for230Vac model.
11.2 Test Condition
Applying 75% loads for the power supply in 40 (+/-5) oC chamber for 4 hours.
12. Harmonics
The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2003 standard of class
D, test at 230Vac 50Hz.
13. Power Factor
The power supply with active power factor correction, and meet the EN61000-3-2 standards,
The power factor is greater than 0.9 at 230V/50Hz, Max. load.
14. Mechanical Specification
14.1 Outline Dimension
Please refer the mechanical drawing of HPC-500-H12S.
14.2 Weight
Maximum weight is 1.5 Kgs.
14.3 Pin Designation
14.3.1 DC CONNECTOR REQUIREMENTS
List or recognized component appliance wiring material(AVLV2),CN,rated min
85
0
C ,300VAC shall be used for all output wiring.