Switching Power Supply Specifications
 
 
 
 
Page 8
 
 
6.  Environments 
6.1  Temperature and Humidity 
6.1.1  Operating 
Temperature   
0 to 40 oC   
Relative Humidity  20 to 90 % 
6.1.2  Storage 
Temperature   
-40 to 70 oC 
Relative Humidity  20 to 95 % noncondensing 
6.2  Altitude 
The power supply can operate normally at any altitude between 0 to 10000 feet. 
6.3  Vibration and Shock 
  Sweep and resonance search for each of X,Y,Z, axis at the sweep. 
RATE of 1/OCTAVE/Min. 
 
Frequency Duration Amplitude 
5-55-10 Hz 
30 minutes 
0.35 mm 
7.  Conducted EMI   
FCC,CE 
8.  Product Safety 
8.1  Safety Requirement 
          
TUV,CB 
8.2  Leakage Current 
The AC leakage current is less than 3.5mA when the power supply connect to 
253Vac/50Hz . 
8.3  Insulation Resistance 
The insulation resistance should be not less than 30M ohm after applying of 500VDC for 1 
minute. 
8.4  Dielectric Voltage Withstand 
The power supply shall withstand for 1 minute without breakdown the application of  a 
60Hz 1500V AC voltage applied between both input line and chassis (20mA DC cut-off 
current). Main transformer shall similarly withstand 3000Vac applied between both 
primary and secondary windings for a minimum of one minute.