6.3.5.11. CONTACT_GET_SET_ETU
This Escape command is used by the HOST to get/set the current ETU for smart cards. Once
set, the new ETU value will take effect immediately.
set, the new ETU value will take effect immediately.
Input:
The input buffer contains the Escape code followed by an 8 bit GET/SET identifier. For SET
ETU, a DWORD specifying the value to be set is following.
ETU, a DWORD specifying the value to be set is following.
Output:
For both Set and Get ETU, the output will be the following.
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Value Description
Wait time
Escape
code(0x80)
code(0x80)
0x01
SET ETU
BIT31-
BIT24
BIT24
BIT23-
BIT16
BIT16
BIT15-
BIT8
BIT8
BIT7-
BIT0
BIT0
0x00
GET ETU
-
-
-
-
Byte0
Byte1
Byte2
Byte3
ETU value
BIT31-BIT24
BIT23-BIT16
BIT15-BIT8
BIT7-BIT0