6.3.5.13. CONTACT_GET_SET_GUARDTIME 
 
This Escape command is used to get/set the Character/Block Guard Time of the reader. The 
guard time is specified in terms of ETU. Once set, the new Guard time will take effect 
immediately. 
Input: 
The input buffer contains the Escape code followed by an 8 bit GET/SET identifier, an 8 bit 
guard time identifier and a 32 bit guard time value in ETU. 
 
Output: 
For Get/Set guard time, the output will be the Character/Block Guard Time value. 
 
 
 
 
 
 
 
 
Byte0 
 
Byte1 
 
Byte2  
 
Byte3 
 
Byte4 
 
Byte5 
 
Byte
Value  Description  Value  Description 
Guard time in ETU 
 
Escape 
code(0x82) 
 
0x01 
 
SET  Guard 
time 
 
0x00 
 
CGT 
 
BIT31-
BIT24 
 
BIT23-
BIT16 
 
BIT15-
BIT8 
 
BIT7-
BIT0 
 
0x01 
 
BGT 
 
0x00 
 
GET Guard 
time 
 
0x00 
 
CGT 
 
 
 
 
 
0x01 
 
BGT 
 
Byte0 
 
Byte1 
 
Byte2 
 
Byte3 
Character Guard time in ETU 
 
BIT31-BIT24 
 
BIT23-BIT16 
 
BIT15-BIT8 
 
BIT7-BIT0