Datalogic PowerScan PD9500 PD9530-HPK1 数据表

产品代码
PD9530-HPK1
下载
页码 362
Enter/Exit Programming Mode
270
PowerScan™ PD9530/PBT9500/PM9500
Set Key Sequence ID 
Sets the identifier for keyboard composed strings. 
$CPWEC
Set keys sequence ID
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at 
left followed by 6 digits from 
The ID characters must be represented by their hexadeci-
mal ASCII code; if the first 2 digits are 0, this feature is dis-
abled. End by scanning the ENTER/EXIT bar code again.
 
Set Key Sequence Header
Sets the header for keyboard composed strings.
$CPWE1
Set key sequence header
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at 
left followed by 32 digits from the Alphanumeric char-
acters in 
the hexadecimal ASCII representation of the desired 
characters. 
If less than the expected string of 16 characters are 
selected, scan the ENTER/EXIT bar code to terminate 
the string. 
If the first 2 digits are 0, the feature is disabled. End by 
scanning the ENTER/EXIT bar code again.
Set Key Sequence Terminator
Sets the terminator for keyboard composed strings.
$CPWE2
Set key sequence terminator
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at 
left followed by 32 digits from the Alphanumeric char-
acters in 
the hexadecimal ASCII representation of the desired 
characters. 
If less than the expected string of 16 characters are 
selected, scan the ENTER/EXIT bar code to terminate 
the string. 
If the first 2 digits are 0, the feature is disabled. End by 
scanning the ENTER/EXIT bar code again.