References
298
PowerScan™ PD9530/PBT9500/PM9500
Aiming Duration Time
Specifies the frame of time the aiming pointer remains on after decoding a 
label, when in trigger single mode. The range for this setting is from 1 to 
255 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 
= 000, 5 = 005, 20 = 020, etc.
3. Go to 
 and scan the ENTER/EXIT PROGRAMMING MODE bar code 
to enter Programming Mode.
4. Scan the bar code: SELECT AIMING DURATION TIME SETTING.
5. Scan the appropriate three digits from the keypad in 
, that represent the duration which was determined in the steps 
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar 
code to abort and not save the entry string. You can then start again 
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See 
 for some examples of how to 
set this feature.
Table 43. Aiming Duration Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
1 Second
90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25 
min.)
2
Pad leading zero(es)
001
090
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT AIMING DURATION TIME SETTING
5
Scan Three Characters 
From 
‘0’, ‘0’ and ‘1’
‘0’, ‘9’ and ‘0’
‘1’, ‘8’ and ‘0’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE