Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode. 
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad 
the result with leading zeroes to yield two digits. For example: 0 = 00, 
5 = 05, 20 = 20, etc.
 and scan the ENTER/EXIT PROGRAMMING MODE bar code 
to enter Programming Mode.
4. Scan the bar code: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in 
 
representing the duration which was determined in the steps above. 
You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar 
code to abort and not save the entry string. You can then start again 
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See 
 for examples of how to set this 
feature.
Table 44. Flash On Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.)
5200ms (5.2 
sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad 
with leading zeroes to yield 
two digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH ON TIME SETTING
5
Scan Two Characters From 
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
 ‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE