Stand Mode Off Time
This feature specifies the amount of time reader illumination stays off after 
pulling the trigger when in Stand Mode. The configurable range is 01 to 32 
by 01 in increments of 500ms (500ms to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits. For example: 2 = 
02, 5 = 05, 20 = 20, etc.
3. Go to 
 and scan the ENTER/EXIT PROGRAMMING MODE bar code 
to enter Programming Mode.
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits from the keypad in 
, that represent the setting which was determined in the steps 
above. You will hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See 
 for some examples of how to 
set this feature.
Table 41. Stand Mode Off Time
STEP
ACTION
EXAMPLES
1
Desired Setting
500 ms
1 Second
5.5 Seconds
16 Seconds
2
Pad leading zero
01
02
11
32
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT STAND MODE OFF TIME
5
Scan Two Characters From 
‘0’ and ‘1’
‘0’ and ‘2’
‘1’ and ‘1’
‘3’ and ‘2’
6
Scan ENTER/EXIT PROGRAMMING MODE