Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册

下载
页码 754
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
10.3 GOT Side Settings
10 - 11
9
ME
LSECNE
T
/H 
CONN
E
CT
ION (P
LC 
T
O
 P
L
C NE
T
W
ORK)
10
ME
LSE
C
N
E
T/10
 
CONNECTION
 (P
LC 
T
O
 P
LC NE
T
W
ORK)
11
CC
-Lin
k I
E
 C
O
N
TRO
LL
E
NE
TW
ORK
 
C
O
NNE
CT
IO
N
12
CC
-L
ink IE
 FIELD 
NETWORK 
CONNECTION
13
CC
-Li
nk C
O
NN
ECTI
O
N
 
(INTELLIGEN
T
 D
EVICE 
ST
AT
IO
N)
14
CC-Lin
CONNECTION 
(V
ia G4)
15
IN
VER
TER 
CONNECTION
16
SE
R
V
O AMP
LI
F
IE
CONNE
C
T
ION
10.3.4 Switch setting (Only when 
MELSECNET/10 
communication unit is used)
POINT
POINT
POINT
Switch setting of the communication unit
When using the MELSECNET/H communication unit,
the switch setting is not needed.
For details of each setting switch and LED, refer to the
following manual.
GT15 MELSECNET/10 communication unit 
User's Manual
(1) Network number setting switch
(2) Group number setting switch
*1
The GOT does not use the group number.
Specify "0".
(3) Station number setting switch
(4) Mode setting switch
POINT
POINT
POINT
(1) Switch setting example
For the switch setting example, refer to the 
following.
(2) When the switch setting is changed
When changing the switch setting after mounting 
the MELSECNET/10 communication unit to the 
GOT, reset the GOT.
(3) Self check test
Select "6" to "9" as the mode setting switch to 
provide a self check test of the MELSECNET/10 
communication unit.
For details, refer to the following manual.
GT15 MELSECNET/10 communication unit 
User's Manual
Network number setting 
switch
Description
Set value
Set the network No. of 
the MELSECNET/10 
communication unit.
(Default: 001)
1 to 239
Group number setting 
switch
Description
Set value
Set the group No. of the 
MELSECNET/10 
communication unit.
(Default: 0)
0: 
No group 
setting (fixed)
*1
8
0
7
F
6
E
5
D
4
C
3
B
2
A
1
9
MODE
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
STATION 
No.
X10
X1
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
NETWORK 
No.
X10
5
0
6
1
7
2
8
3
9
4
X100
X1
5
0
6
1
7
2
8
3
9
4
GROUP No.
RUN 
PC 
 
DUAL 
SW.E 
M/S.E 
PRM.E 
CRC 
OVER 
AB.IF 
TIME 
DATA 
UNDER 
LOOP 
SD 
RD
POWER 
 
 
D.LINK 
T.PASS 
 
GOT R/W 
CRC 
OVER 
AB.IF 
TIME 
DATA 
UNDER 
LOOP 
SD 
RD




R




R
F.LOOP 
 
R.LOOP 
 
GT15-75J71LP23-Z, GT15-75J71BR13-Z
(4)
(2)
(1)
(3)
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
NETWORK 
No.
X10
5
0
6
1
7
2
8
3
9
4
X100
X1
5
0
6
1
7
2
8
3
9
4
GROUP No.
Station number setting 
switch
Description
Set value
Set the station No. of the 
MELSECNET/10 
communication unit.
Set to not duplicate other 
stations in the network.
(Default: 01)
1 to 64: GT15-
75J71LP23-Z
1 to 32: GT15-
75J71BR13-Z
Mode setting switch
Description
Set value
On-line 
(Default: 0)
0
5
0
6
1
7
2
8
3
9
4
5
0
6
1
7
2
8
3
9
4
STATION 
No.
X10
X1
8
0
7
F
6
E
5
D
4
C
3
B
2
A
1
9
MODE