Mitsubishi Electronics Mitsubishi Digital Electronics Portable Multimedia Player GOT1000 用户手册

下载
页码 754
10 - 12
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
10.4 PLC Side Setting
10.4 PLC Side Setting
10.4.1 Connecting to MELSECNET/H 
network module
This section describes the settings of the GOT and 
MELSECNET/H network module in the following case of 
system configuration.
When connecting the MELSECNET/H network module to 
the MELSECNET/10 network system, specify the 
MELSECNET/10 Mode as a network type.
POINT
POINT
POINT
MELSECNET/H network module
For details of the MELSECNET/H network module,
refer to the following manual.
Q corresponding MELSECNET/H Network 
System Reference Manual (PLC to PLC 
network)
System configuration
*1
The MELSECNET/H network module is mounted at slot 0 of 
the base unit.
The start I/O No. of the MELSECNET/H network module is 
set at "0".
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the MELSECNET/H network module is set to "70".
Switch setting of MELSECNET/H network 
module
Set the station number setting switch and mode setting 
switch.
Model name
Reference
MELSECNET/H network module
QJ71LP21, 
QJ71LP21-25, 
QJ71LP21S-25, 
QJ71BR11
MELSECNET/10 network 
module
(QnA Series)
AJ71QLP21, 
AJ71QLP21S, 
AJ71QBR11, 
A1SJ71QLP21, 
A1SJ71QLP21S, 
A1SJ71QBR11
MELSECNET/10 network 
module
(A Series)
AJ71LP21, 
AJ71BR11, 
A1SJ71LP21, 
A1SJ71BR1
<MELSECNET/H network module> *1 
(Use the default value for settings other than the following.)
  Station No. 
     : 1
  Mode 
 
     : Online (10Mbps)
  Network type 
     : MNET/10 mode (Control station)
  Network No. 
     : 1
  Total stations 
     : 2
  Network range assignment: LB0000
H
 to LB00FF
H
 
MELSECNET/10 (PLC to PLC network)
<GOT> (Use the default value for settings other 
              than the following.)
Station No. 
   : 2
Mode 
 
   : Online
Network No. 
   : 1
Network range assignment: LB0100
H
 to LB01FF
H
LW0100
H
 to LW01FF
LW0000
H
 to LW00FF
H
MNG 
D.LINK 
RD 
L ERR.
RUN 
T.PASS 
SD 
ERR.
QJ71LP21-25
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
QJ71LP21
-25
IN
OUT
EXT.PW
+24V
24G
24G
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
IN
OUT
MNG 
D.LINK 
RD 
L ERR.
RUN 
T.PASS 
SD 
ERR.
QJ71LP21S-25
QJ71LP21 S-25
EXT.PW 
EXT.PW
+24V
24G
(FG)
MNG 
D.LINK 
RD 
L ERR.
RUN 
T.PASS 
SD 
ERR.
0
5
9
4
8
3
7
2
6
1
0
5
9
4
8
3
7
2
6
1
STATION NO.
X10
X1
MODE
0
8
F
7
E
6
D
5
C
4
B
A
3
2
9
1
QJ71BR11
QJ71BR11
(1)
(2)
(1)
(2)
(1)
(2)
QJ71LP21, QJ71LP21-25
QJ71LP21S-25
QJ71BR11