Maretron FPM100 用户手册

下载
页码 23
 
FPM100 User’s Manual  
 
Keep in mind that the rated burst pressure of the pressure transducer is 2.4 to 3 times the 
maximum measurement pressure of the transducer. If the pressure transducer will experience 
pressure spikes in excess of the transducer’s maximum measurement pressure, use of a 
Pressure Snubber (PT-SNUB-01) accessory is highly recommended. The snubber will dampen 
pressure spikes that will be seen by the pressure transducer. 
 
Please refer to the installation instructions packaged with the pressure transducer accessory 
for detailed installation instructions for the transducer itself. 
 
2.4.2  Tank Level Measurement Applications 
The pressure transducer should be mounted to a properly sized fitting on the side of the tank 
as close as possible to the tank bottom. The pressure transducer cannot provide an accurate 
measurement when the fluid level is below the level of the pressure port of the pressure 
transducer. Please refer to Figure 4 below for an example of pressure transducer mounting on 
the side of the tank. 
 
Below Sensor Port, so 
Cannot be Measured 
Full Tank Depth 
Pressure Transducer 
 
 
Figure 4 – Fluid Level Measurement with Pressure Transducer 
 
It is highly recommended that a ball valve be mounted between the pressure transducer and 
the tank. This allows the pressure transducer to be serviced without draining the tank. Please 
refer to Figure 5 below for an example of the installed ball valve. 
 
 
 
 
 
Page 6  
 
Revision 1.3