Maretron FPM100 用户手册

下载
页码 23
 
FPM100 User’s Manual  
 
Figure 6 – NMEA 2000
®
 Connector Face Views 
2.5.2  Pressure Transducer Connections 
The FPM100 pressure transducer connections are made by connecting to the 12-pin terminal 
strip on the top of the unit.  First, remove the four screws at the corners of the unit detaching 
the splash guard from the unit.  On the bottom of the splash guard, you will find a label 
detailing the wire connection to pin number assignments, which are repeated in the table 
below. 
 
Pin # 
Signal Name 
Connection 
P0+ 
Pressure Transducer 0 (positive terminal) 
P0- 
Pressure Transducer 0 (negative terminal) 
P1+ 
Pressure Transducer 1 (positive terminal) 
P1- 
Pressure Transducer 1 (negative terminal) 
P2+ 
Pressure Transducer 2 (positive terminal) 
P2- 
Pressure Transducer 2 (negative terminal) 
P3+ 
Pressure Transducer 3 (positive terminal) 
P3- 
Pressure Transducer 3 (negative terminal) 
P4+ 
Pressure Transducer 4 (positive terminal) 
10 
P4- 
Pressure Transducer 4 (negative terminal) 
11 
P5+ 
Pressure Transducer 5 (positive terminal) 
12 
P5- 
Pressure Transducer 5 (negative terminal) 
 
Please refer to Figure 7 for connecting the FPM100 to a pressure transducer. This figure 
shows the connection of the pressure transducer to channel 0 via the terminals named P0+ 
and P0-.  Connections to other channels are similar.  
Pressure Transducer 
FPM100 Screw Terminals
Red
 
Black or White
 
1 2 
P0+
 
P0-
 
3 6 
10 
11 
12
P1-
P1+
 
 
P2+
 
P2-
 
P3+
 
P3-
 
P4+
 
P4-
 
P5+
 
P5-
 
 
Figure 7 – Pressure Transducer Connection Diagram 
 
 
 
 
 
Page 8  
 