Maretron FPM100 用户手册

下载
页码 23
 
FPM100 User’s Manual  
 
 
 
 
 
Page 10  
 
Revision 1.3 
3.2.2  Configuring Label 
Program this parameter with a text string which identifies the particular parameter being 
monitored by this channel.  Maretron display products will display this label text when you are 
selecting data to display. 
 
3.2.3  Configuring Pressure at 4mA 
Program this parameter to match the pressure reading of the pressure transducer when it is 
sourcing a current of 4mA. You can determine this value by examining the specification of the 
pressure transducer being used. 
 
3.2.4  Configuring Pressure at 20mA 
Program this parameter to match the pressure reading of the pressure transducer when it is 
sourcing a current of 20mA. You can determine this value by examining the specification of the 
pressure transducer being used. 
 
3.2.5  Configuring Source 
You can configure a “Source” descriptor to be transmitted with the pressure reading which is 
used to provide an indication of the source of the pressure data for this channel. Choices are 
as follows: 
1. Water Pressure 
2. Atmospheric Pressure 
3.  Compressed Air Pressure 
4. Hydraulic Pressure 
5. Steam Pressure 
6.  16 User Defined pressure sources (User Defined 129 – User 
Defined 144) 
 
3.2.6  Configuring Data Damping Period 
You can configure a damping parameter to smooth the pressure readings or make them more 
responsive. The data damping is configurable between 0.2-25.0 seconds. The default data 
damping for a channel in Pressure/Vacuum mode is 3.0 seconds. 
 
3.3  Configuring a Channel in Tank Mode 
The following sections describe the parameters that are available for configuration for a 
channel which has been set to Tank mode. 
 
3.3.1  Configuring Label 
Program this parameter with a text string which identifies the particular parameter being 
monitored by this channel.  Maretron display products will display this label text when you are 
selecting data to display.