Ez Access Mobility Aid ez-access 用户手册

下载
页码 16
- 6 - 
1) 
INSTALLING PLATFORMS: 
If your system does not include a platform, skip to ‘INSTALL 
RAMP SECTIONS’ of this instruction guide. Generally, we suggest installing all platforms 
and ramps before installing handrails (see ‘HANDRAIL INSTALLATION’). 
A) 
There are three types of platforms (you may be installing one or more of these 
types). All three require the same procedure for assembly except for FIG. 3 
which requires an additional platform connector kit. 
FIG. 1
  5' x 5' Universal Platform (straight configuration) 
FIG. 2
  5' x 5' Universal Platform (turn configuration) 
FIG. 3
   5' x 4' Universal Platform (2 shown combined to make 5' x 
             
8’ turn back platform)
 
 
 
FIG. 1 
FIG. 2 
 
FIG. 3 
- 27 - 
13) 
INSTALL OPTIONAL LIGHTNING ROD GROUNDING KIT: 
 
A) 
The Lightning Rod Grounding Kit provides a path for lightning strikes into the 
ground. 
 
WARNING:
 Prior to installing the grounding rod, ensure that any underground 
electrical conductors, natural gas lines, water/drain lines, and/or other interferences 
are located and will not hinder the installation. 
i) 
Install the EZ-ACCESS
®
 Modular ramp system. 
ii) 
Drive the grounding rod straight into the ground as close as possible (at 
least within 1½') to one of the support tubes, leaving approximately 2" 
exposed. 
iii) 
Install the hose clamp around support tube. Place #8 copper wire under 
hose clamp and tighten so that wire is in good contact with support tube. 
iv) 
Install 5/8” grounding rod clamp to grounding rod. Place #8 wire between 
clamp and rod, then tighten clamp. 
FIG. 42