5708009-C
Advanced Energy
®
130
read 
mainframe 
software 
version 
number
Requests the version number of the 
mainframe software. The returning packet 
contains 7 ASCII characters—a 7-digit 
number. This command is used in 
conjunction with CMD 198 to obtain the 
version/revision number of the mainframe 
software.
0
7  data  bytes
7 ASCII 
characters
140
report host 
time-out 
value
Requests the serial Host port time-out value 
(002 to 500 representing 0.02 to 5.00 s).
0
2  data  bytes
16-bit value
154
report 
regulation 
mode
Requests regulation mode (set with CMD 3). 
Returning values:
• 6 = Forward
• 7 = Delivered or Load
• 8 = External (DC Bias)
1 data byte
8-bit value
155
read control 
method
Requests control mode (set by CMD 14). 
Returning values: 2 = host, 4 = analog
0
1  data  byte
8-bit value
156
read active 
target
Requests the number of the active target (set 
by CMD 11)
0
1  data  byte
8-bit value
157
read target 
life
Requests the amount of life remaining in the 
target you specify (set by CMD 12). This 
command requires 1 data byte to specify the 
number of the target you request (1 to 4).
Note: A decimal is implied—100 = 1 kWh,
1 data byte
8-bit value
4 data bytes
32-bit value