LATCHING ZONE TYPES 
 
When any device (other then FIRE or GAS) is connected to SWITCH 12V or a Switched Power Output, the zone must be 
configured as one of the LATCHING ZONE TYPES (latching perimeter, latching night interior, latching away interior, and 
latching tamper).  LATCHING ZONE TYPES ignore the status of that zone during power cycles.  
 
Used primarily when the FIRE ALARM VERIFICATION feature is being used or if more than one area is being protected.  This 
type will ignore the status of LATCHING ZONES (i.e. Glassbreak Detectors) when the power is switched to reset devices.  
 
 
DESCRIPTION OF ZONE TYPES 
 
ENTRY/EXIT 
 
 
ENTRY/EXIT ZONE types are intended for doors.  ENTRY/EXIT ZONES are armed in security modes DAY, NIGHT, AWAY, 
and VACATION.  In DAY and AWAY modes, there is an entry delay (defined by ENTRY DELAY) on ENTRY/EXIT ZONES 
to allow you to get into the house and turn off the alarm before it sounds.  In NIGHT & DAY INSTANT mode, there is no entry 
delay, so that the alarm sounds immediately if someone opens a door. 
 
There are two special types of ENTRY/EXIT ZONES for use with garage doors, or doors that are far away from the control 
console.  They are called DOUBLE ENTRY DELAY and QUADRUPLE ENTRY DELAY zones.  These zones have double or 
quadruple the ENTRY DELAY to give you additional time to reach the console to disarm the system upon returning.  Only the 
ENTRY DELAY is extended on these zone types.  The EXIT DELAY is not extended. 
 
If an ENTRY/EXIT ZONE is tripped first, all other zones will are delayed. 
 
PERIMETER and LATCHING PERIMETER 
 
PERIMETER ZONE types are intended for windows and exterior doors not requiring an entry delay.  All PERIMETER ZONES 
are armed in security modes DAY, NIGHT, AWAY, and VACATION.  There is not an entry delay on a perimeter zones.  If a 
window or door on this zone is opened while the security system is in DAY, NIGHT, AWAY or VACATION mode, the alarm 
will sound immediately.  LATCHING PERIMETER ZONES ignore the status of that zone during power cycles.  
 
 
NIGHT INTERIOR and LATCHING NIGHT INTERIOR 
 
NIGHT INTERIOR ZONES are intended for motion detectors in areas where no one should be while you are sleeping in your 
home.  For example, if you have a two-story home and sleep upstairs, your downstairs motion detector(s) should be on a NIGHT 
INTERIOR ZONE. 
 
NIGHT INTERIOR ZONES are armed in security modes NIGHT, VACATION, and AWAY only.  There is no delay on a 
NIGHT INTERIOR ZONE.  Night interior zones are NOT armed in DAY or DAY INSTANT mode, so that you may move about 
freely in your home when the security system is in DAY or DAY INSTANT mode, while still having the windows and doors 
protected.  LATCHING NIGHT INTERIOR ZONES ignore the status of that zone during power cycles. 
 
AWAY INTERIOR and LATCHING AWAY INTERIOR 
 
AWAY INTERIOR ZONES are for areas of your home where no one should be while you are away.  In the previous example, 
your upstairs motion detector(s) should be on an AWAY INTERIOR ZONE.  AWAY INTERIOR ZONES are armed only when 
the security mode is AWAY.  LATCHING AWAY INTERIOR ZONES ignore the status of that zone during power cycles. 
 
PANIC, TAMPER, and LATCHING TAMPER 
 
 
PANIC and TAMPER ZONES are for emergency pushbuttons and tamper switches.  PANIC and TAMPER ZONES are always 
armed, even if the security mode is OFF.  There are no delays on PANIC and TAMPER ZONES.  An emergency dial out is 
activated after the DIAL OUT DELAY.