TAMPER ZONES should be used for items such as gun cabinets and liquor closets. 
 
LATCHING TAMPER ZONES ignore the status of that zone during power cycles. 
 
POLICE EMERGENCY 
 
This zone type activates the burglar alarm and sounder.  An emergency dial out is activated after the DIAL OUT DELAY.
 
 
DURESS EMERGENCY (SILENT DIAL OUT)  
 
If you wish to have a button in your home that activates a SILENT dial out, (no lights flashing and no sounder) it should be 
connected to a zone that is configured as a DURESS EMERGENCY.  If this zone is accidentally tripped, you will not know that 
the Omni II is making a silent dial out, and hence won't know to stop it. 
 
To stop a silent dial out once it has started, you must go to the console and press OFF then enter your code. 
 
SUPERVISED FIRE  
 
Any zone can be programmed as a SUPERVISED FIRE ZONE.  In UL Listed Installations, all fire detectors must be configured 
as a SUPERVISED FIRE ZONE and connected as shown in this manual.  When Zones 1-4 are configured as a SUPERVISED 
FIRE ZONE, the corresponding Zone Jumpers (JP11-JP14) must be in the "SMK" (smoke) position. 
 
FIRE EMERGENCY  
 
This zone type activates the fire alarm for a normally closed (open for alarm) and open collector (short to ground for alarm) 
switches.  It is not supervised as required for UL Listed Installations and shall NOT be used in such installations. 
 
GAS 
 
This GAS ZONE will generate an alarm, activate the sounder (on - off - on - long off), and make a dial out.  This zone type 
requires an external 1000-ohm end-of-line resistor.
 
When Zones 1-4 are configured as a GAS ZONE, the corresponding Zone 
Jumpers (JP11-JP14) must be in the "SMK" (smoke) position. 
 
AUXILIARY EMERGENCY 
 
This AUXILIARY EMERGENCY ZONE type will generate an alarm (console beeper - no sirens) and make an emergency dial 
out when the zone is violated.  An emergency dial out is activated after the DIAL OUT DELAY. 
 
TROUBLE
 
 
This zone type can be used to monitor the status of an external device, such as the battery status of a wireless security receiver.  It 
can also used to record events in the event log (i.e. driveway activation, opening of a gate, etc.) without setting off the alarm.  
 
When the zone is tripped, the zone name will be displayed on the display as "NOT RDY".  The alarm is not activated, regardless 
of the security mode.  The trouble is logged in the event log.  The digital communicator (if used) will report the alarm code for the 
zone.  The voice dialer will not be activated.   
 
FREEZE 
 
This FREEZE ALARM ZONE type will generate an alarm (console beeper, no sirens) and make an emergency dial out. 
 
WATER 
 
This WATER ALARM ZONE type will generate an alarm (console beeper, no sirens) and make an emergency dial out.