Viking RVCH330X 安装指导

下载
页码 8
5
IMPORTANT–
Please Read and Follow!
4
W A R N I N G
TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS
R  ange hoods must be installed
with the ventilators that are
specified on their carton
indicating suitability with this model. Other
ventilators cannot be substituted.
C A U T I O N
For general ventilating use only. DO NOT use
to exhaust hazardous or explosive materials
and vapors.
W A R N I N G
TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGETOP
GREASE FIRE, OBSERVE THE
FOLLOWING. (Based on “Kitchen Firesafety
Tips,” published by NFPA.)
1. SMOTHER FLAMES with a close fitted lid,
cookie sheet, or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN. You
may be burned.
3. DO NOT USE WATER, including wet
dishcloths or towels a violent steam
explosion will result.
4. Use an extinguisher ONLY if
• You know it is a Class ABC extinguisher,
and you already know how to operate it.
• The fire is small and contained in the area
where it started.
• The fire department is being called.
• You can fight the fire with your back to an
exit.
RVCH Classic Chimney Wall Hoods w/Standard Ventilator 
Description
30”
36”
Duct cover width
16” (40.6 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
18” (45.7 cm) to 30” (76.2 cm)
Number of lights
2
Number of filters
2
Interior ventilator kit
460 CFM
Interior duct size*
7” (17.8 cm)
Interior—Maximum amps
5.6
* Disregard when using recirculating kits.
460 CFM blower is shipped with hood.
NOTE:
All products must be hard wired with 2-wire with ground.
24”
(61.0 cm)
16”
(40.6 cm)
12”
(30.5 cm)
18”
(30.5 cm)
to
30”
(76.2 cm)
12”
(30.5 cm)
A
A (Hood width)
30”W.          29-7/8” (75.9 cm)
36”W.          35-7/8” (91.1 cm) 
2”
(5.1 cm)
Dimensions & Specifications
(RVCH Classic Chimney Wall Hoods w/Standard Ventilator)
NOTE:
Duct cover included.