Installation Instructions
Ground
Power Input
Blower Output
Electrical access 
panel
Raised Vent 
 Electrical Access Panel
Raised Vent  
Front View
To power wiring/conduit.
Connect other end of 
wires to blower terminal 
block.
Wires to power plug. 
Pre-wired at factory. 
Do not modify.
Attach ground wire 
as shown
Match wire colors to 
terminals as shown.
BLACK
WHITE
GREEN
Electrical Installation
 WARNING
ELECTRIC SHOCK HAZARD - Do not connect the 
raised vent power plug to the electrical outlet until 
installation is complete.
•  Failure to complete electrical connections properly 
may result in an electric shock hazard or a damaged 
or non-functional system. Follow the wiring diagrams 
carefully to ensure a proper installation. Do not 
change the factory wired terminal connections inside 
the electrical access panel for the raised vent or the 
blower.
•  To avoid an electric shock hazard and to prevent dam-
age route all wiring away from hot surfaces.
1.  Run the wiring/conduit line used to supply power from 
the raised vent to the blower parallel to the duct work.
2.  Make sure the raised vent power plug is disconnected 
from the electrical outlet.
3.  Remove the cover from the raised vent electrical 
access panel. 
4.  Connect the wiring/conduit to the blower according to 
the wiring diagrams on this page, the facing page and 
local codes and ordinances. Make sure all terminal 
connections, including the factory wired connections, 
are tight.
5.  Replace the electrical access panel.