5.  Drill 2 pilot holes through each of the undercounter mounting 
 
brackets into the underside of the countertop. Using 2 screws 
 
(not provided) of the appropriate length, mount the brackets to 
 
the countertop. 
IMPORTANT: Select a screw length that will not allow the screws to 
go through the countertop when tightened. 
A
B
C
A. Screws
B. Backsplash
C. Countertop
6.  Check that the downdraft vent is level vertically. Loosen the lower 
 
support legs screws and position the legs against the cabinet 
 
floor.
7.  Fasten the lower support legs to the cabinet floor with screws 
 
(not provided). 
8.  Tighten the lower support legs screws.
Control Installation 
Before the control installation, make sure you have made the 
 
cutouts to proceed (see “Countertop Dimensions Chart”).
Place the control base on location and mark the holes with a 
 
pencil. Put the base aside.
Drive the installation screws on the marked points. Once you 
 
have inserted the screws, remove them.
Place the control base in place and drive the installation screws 
 again.
A
B
C
D
A. Countertop
B. Control cutout
C. Control base
D. Mounting screws
Run the control cable through the countertop hole.
Push down the control assembly against the control base, until 
 
you hear the click. 
Electrical Connection 
 
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating. 
Failure to do so can result in death or electrical shock
1.  Disconnect power.
2.  Feed the power supply cable through the conduit connector 
 
and into the terminal box. 
 
WARNING 
Electrical Shock Hazard 
Electrically ground blower. 
Connect ground wire to green and yellow ground wire in terminal 
box. 
Failure to do so can result in death or electrical shock. 
3.  Connect the green (or green/yellow) ground wire to the green 
 
or yellow/green ground wire using UL listed wire connectors.
4.  Tighten the screw on the conduit connector.
5.  Connect the 2 white wires together using UL listed wire 
 connectors. 
A
D
B
F
C
E
A. Green or green and yellow ground wire
B.White wires
C. UL listed wire connectors
D. Black wires
E. UL listed or CSA approved conduit connector
F. Downdraft vent wiring