Elica ERS63XSS 安装指导
9
Rear mounting (reversible mode)
Optional blower motor rear mounting position (opposite side) for is-
land cabinet locations. The aspiration assembly (metalic plate, filters),
can be moved to the opposite side (rear) of the vent.
A
B
C
A. Motor box
B. Aspiration orientation
C. Cooktop
1. Move the aspiration plate and the grease filters and put them
aside. (See the Cleaning section).
2. With the help of a flat head screwdriver, gently take off the
aspiration plate plastic clips.
3. Once the clips were removed from the aspration assembly, retire
the screws and washer as shown the image below. Put the
screws aside.
4. Unplug the electrical conexion of the aspiration assembly, and
remove it from the hood.
5. Remove the mounting screws from the aspiration structure as
shown the image below.
B
A
A. Aspiration structure
B. Installation screws
6. Lift the structure and flip it to the opposite side and fix with the
same screws previously removed.
7. Plug the electrical conexion and put it into place.
8. Put back the screws and metal washers to the aspiration
assembly. Insert the plastic clips back.
9. Relocate the grase filters and the aspiration plate.