Elica ERS63XSS 安装指导

下载
页码 14
9
Rear mounting (reversible mode)
 
Optional blower motor rear mounting position (opposite side) for is-
land cabinet locations. The aspiration assembly (metalic plate, filters), 
can be moved to the opposite side (rear) of the vent. 
A
B
C
A. Motor box
B. Aspiration orientation
C. Cooktop
1.  Move the aspiration plate and the grease filters and put them 
 
aside. (See the Cleaning section).
2.  With the help of a flat head screwdriver, gently take off the  
 
aspiration plate plastic clips.  
3.  Once the clips were removed from the aspration assembly, retire 
 
the screws and washer as shown the image below. Put the 
 
screws aside. 
4.  Unplug the electrical conexion of the aspiration assembly, and 
 
remove it from the hood. 
5.  Remove the mounting screws from the aspiration structure as 
 
shown the image below. 
B
A
A. Aspiration structure
B. Installation screws
6.  Lift the structure and flip it to the opposite side and fix with the 
 
same screws previously removed. 
7.  Plug the electrical conexion and put it into place.
8.  Put back the screws and metal washers to the aspiration  
 
assembly. Insert the plastic clips back.
9.  Relocate the grase filters and the aspiration plate.