Countertop Cutout Dimensions 
IMPORTANT: Countertops with a bull-nosed front edge are not rec-
ommended for these installations.
Some models require a countertop deeper than 25” (63.5 cm); see the 
following “Countertop Cutout Dimensions Chart.”
To avoid mistakes, it is recommended that the cooktop and vent 
cutouts be drawn on the countertop before making any cutouts.
See the Installation Instructions that came with your cooktop for com-
plete cutout dimensions, location dimensions and installation
details.
D
E
C
B
F
G
H
I
A
A. Downdraft vent
B. Cooktop
C.Measurement of cooktop rear overhang
D. D = Measurement of cooktop rear over-
hang (C) + 2
1
2
” [61 mm] (E)
E. 1
13
16
” (46.2 mm)
F. ½” (12.7 mm) minimum
G.¼” (6.4 mm) minimum
H. Countertop and backsplash
I. ½” (12.7 mm) minimum
 
Countertop Cutout Dimensions Chart
A
B
D
E
F
C
A. ½” (12.7 mm) minimum to backsplash or 
rear wall
B. 
3
4
” (19.1 mm) maximum backsplash depth
C. 27½” (69.9 cm) on 30” (76.2 cm) models
    33½” (85.9 cm) on 36” (91.4 cm) models
D. D = Measurement of cooktop rear  
     overhang + 1
13
16
” (46.2 mm)
E. Ø 2
9
16
” (6.5 cm). The control can be 
     installed in both left or right sides.
F.  Minimum distance from cooktop 4” (10 cm) 
     maximum distance from cooktop 8” (20 cm)
 
Venting Requirements 
IMPORTANT: Make sure there is proper clearance within the wall
or floor before making exhaust vent cutouts.
Use heavy (rigid) metal vent.
Venting system must terminate to the outside.
Do not terminate the vent system in an attic or other enclosed 
 area.
Do not use 4” (10.2 cm) laundry-type wall caps.
Do not install 2 elbows together.
Do not use plastic or metal foil vent.
The length of vent system and number of elbows should be 
 
kept to a minimum to provide efficient performance.
Use no more than three 90° elbows
Make sure there is a minimum of 24” (61 cm) of straight vent 
 
between the elbows if more than one elbow is used.
Use clamps or duct tape to seal all joints in the vent system.
Use caulking tape to seal the exterior wall or floor opening 
 
around cap.
Do not cut joist or stud. If vent cutout falls over a joist or stud, 
 
a supporting frame must be constructed.
Flexible metal vent is not recommended. If it is used, calculate 
 
each foot of flexible vent as 2 ft (0.6 m) of rigid metal vent. 
 
Flexible elbows count twice as much as standard elbows.
Recommended vent system length:
For either interior-mounted or exterior-mounted blower
installations, the vent system length should not exceed the
maximum lengths listed in the Maximum Length of Vent System
chart. See “Calculating Vent System Length” in the “Venting
Methods” section in the Installation Instructions.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent
system. The damper should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.