Installation Instructions
Venting Methods
Determine which venting method is best for your application.
Vent system can terminate either through the wall or floor.
 
Island locations
Front (standard) mounted
blower motor
Rear mounted blower motor 
(Reversible version)
C
B
A
C
B
A
A. Down vent
B. Cooktop
C. Aspiration plate
Built-in cabinet locations
A
B
C
A. Down vent
B. Left vent
C. Right vent
 
Island locations 
Vent systems installed under a concrete slab using PVC sewer 
pipe.
 
Front (standard) mounted blower motor
B
C
M
A
L
K
J
I
H
G
E
F
D
Rear mounted blower motor (reversible aspiration plate)
B
D
E
F
G
H
I
J
K
A
M
C
L
A. Wall cap
B. 6” (15.2 cm) round metal vent
C.16” (40.6 cm) maximum
D. 6” (15.2 cm) round PVC swer pipe
E. 6” (15.2 cm) round metal vent transi-
tion with damper (supplied)
F. 6” (15.2 cm) round PVC coupling 
G. Concrete slab
H. 6” (15.2 cm) round PVC sewer pipe
I. 6” (15.2 cm) round 90º PVC sewer       
     pipe elbow
J. Tightly pack gravel or sand 
    completely around pipe
K. 6” (15.2 cm) round 90º PVC sewer       
     pipe elbow
L. 6” (15.2 cm) round PVC coupling
M. 12” (30.5 cm) minimum
Installing the vent system
 
WARNING
Excessive Weight Hazard
Use two or more people to move and install downdraft vent.
Failure to do so can result in back or other injury. 
1.  Place cardboard or similar material on top of a flat surface where 
 
you can easily assemble the downdraft vent system.
2.  Remove parts packages, downdraft vent and blower box from the 
 carton.
3.  Remove all shipping materials, tape and film from the downdraft 
 
vent and blower box.
4.  Install the right and left undercounter mounting brackets to the 
 
vent box. Slide the keyhole slots over the guide tabs and push 
 
the brackets up to set them in place.
A
B
C
D
A. Vent box
B. Undercounter mounting bracket
C. Keyhole slots
D. Guide tabs
5.  Attach the end cap to the vent box, depending on what vent  
 
position you choose (standard-reversible). Place the tabs into the  
 
mounting slots at each end of the downdraft vent as shown and 
 
push down to lock into place. 
A
B
C. Standard installation cap