6.  Measure distance “X” from the cabinet floor to the top of the 
 
countertop. Subtract 28
1
2
” from distance “X” to determine  
 
dimension “Y” (X - 28
1
= Y).
Top of countertop
“X”
“Y”
Cabinet floor
28
1
2
(73 cm)
Downdraft
vent
7.  Attach the support legs to the side of the vent box with 
 
4 - 4 x 8 mm screws in each support leg. Adjust to dimension 
 
“Y” from the bottom of the vent box to the bottom of the support 
 
legs. Tighten screws. 
A
C
B
dim. “Y”
A. Motor box
B. Support leg
C. Installation screws
Determine which vent direction 
is best for your installation
 
When installed in a cabinet, vent system can exhaust through the
bottom, right or left of the cabinet.
IMPORTANT: When using the 6” (15.2 cm) vent transition (supplied) 
for 6” round venting, only left or right venting is recommended.
Bottom venting
NOTE: If installing the vent damper in the down position, a wall or
roof cap with a damper at the exit end of the vent system is required.
Downdraft vent is shipped with blower in down venting position so 
 
no modification is required.
If rear mounting of the blower motor is not required, go to the 
 
“Complete Installation” section.
To mount the blower motor to the rear side of the vent box, go to 
 
the “Rear Mounting - Blower Motor” section.
Left or right venting:
1.  Using two or more people, place the downdraft vent system on its 
 back.
2.  Remove the 4 screws from the cover plate mounted to the face of 
 
the motor box and set them aside.
B
A
D
E
F
G
C
A.Cover plate
B. Cover plate screws
C. Cover plate keyhole slot shoulder screws
D.Motor mounting screws
E. Vent cover plate
F. Motor box
G. Vent cover screws
3.  Slide the cover plate up and slip it over the keyhole slot shoulder 
 
screws. Set the cover aside.
4.  Remove 4 screws from the bottom of the motor box that hold 
 
the motor assembly to the motor box. 
 
NOTE: Disconnect the electrical wiring connection from motor if 
 needed.
5.  Remove 3 screws and the vent cover plate from the left or right 
 
side of the motor box for the venting direction to be used.
6.  Rotate the blower motor assembly 90 degrees to the left or right  
 
side to the chosen venting direction and secure to the blower box 
 
with motor mounting screws previously removed. Do not twist or 
 
bind the wires.
7.  Install the vent cover plate over the rectangular opening in the 
 
bottom of the motor box and secure with vent cover screws. 
 
NOTE: Reinstall the electrical wiring connection to motor if 
 removed.
8.  Reinstall the cover plate to the face of the motor box and secure 
 
with 4 cover plate screws previously removed.
9.  For mounting the blower motor to the back of the vent box, go 
 
to the “Rear Mounting - Blower Motor” section. Otherwise, go to 
 
the “Complete Installation” section.