3.3 
CUSTOMIZING SETTINGS FOR YOUR SYSTEM 
You can customize the settings of the DVR395 to fit your system using the OSD and front panel 
push buttons. 
To edit settings, perform the following procedures and 
see Table 7 (Page 23). 
• 
Power up the unit. 
• 
Connect a terminal for the On Screen Display.  
See Section 
3.2
 (Page 23). 
• 
Access the Main Menu by pressing either the 
<SELECT> or <ENTER> push button on the 
front panel. 
• 
Using the front Panel <SELECT> button, 
select/highlight the item you wish to edit. 
• 
Press the <ENTER> push button to display that screen. 
NOTE:  The values shown on the following screens are examples only, and will likely be 
different in normal operation. 
For Carrier Select: 
• 
From the Main Menu, select “Carrier Select.” 
• 
Press <ENTER> to display the “Carrier Select” 
screen. 
• 
Press <ENTER> to enter the edit field. 
• 
Use <SELECT> to place the cursor on the digit to 
be edited. 
• 
Use the <ENTER> button to cycle the digit. 
• 
Use <SELECT> to move to the next item in the 
scroll menu. 
• 
Make further edits, if desired. 
• 
Use <SELECT> to highlight “Activate Selection.” 
• 
Press <ENTER> to save the new settings and exit this screen. 
• 
To exit without saving the changes, Select “Return To Main Menu” and press <ENTER>. 
Main Menu 
 
Carrier Status 
Signal Strength 
Carrier Select 
Serial Port Select 
Software Version 
Exit 
CARRIER SELECT 
From Table: 
Carrier (MHz): 
12000.00 
Data Rate (Mbps)  4.992 
FEC Rate: 
½ 
Tag Site: 
MPEG Mode: 
TRANSPORT 
LNB LO (MHz) 
10750.00 
Activate Selection 
Return To Main Menu