RECORDING
Use the following procedure to record the monitored video 
in the normal recording area.
Recording will not be possible until a time has been set for 
the digital video recorder. Make sure to set the time. 
(JP.14)
1
Press the [REC/STOP] button.
The REC/STOP indicator lights up, “REC” appears on-
screen (i.e., the recording symbol), and recording starts.
z
When recording for the first time, the default settings 
are used. For details regarding modification of the 
picture quality or recording rate, see P.62.
z
When the space remaining in the normal recording area 
drops below a preset value, the FULL indicator on the 
digital video recorder’s front panel starts to flash. If 
recording is continued beyond this point, the normal 
recording area will become full, recording will stop, and 
the FULL indicator will stop flashing and remain lit. In 
such a case, use the <RECORDING AREA SET> 
screen to perform “AREA FULL RESET” for the normal 
recording area, thus allowing recording to start again 
from the beginning. (JP.60)
z
Playback is possible even while recording. See P.22 for 
more details.
2
Press and hold the [REC/STOP] button 
for approximately 3 seconds.
“REC” disappears from the operation display and 
recording ends.
Use the following procedure to record the monitored video 
for a preset length of time in the normal recording area.
Recording will not be possible until a time has been set for 
the digital video recorder. Make sure to set the time. (JP.14)
1
Press the [TIMER] button.
The TIMER indicator lights up and the digital video 
recorder enters timer recording standby mode. 
(1) See P.65 for more details on timer recording settings.
(2) At the time specified for the start of timer recording, the 
REC/STOP indicator lights up, “REC” appears on-
screen (i.e., the recording symbol), and recording starts. 
(3) At the time specified for the end of timer recording, the 
TIMER and REC/STOP indicators turn off, and 
recording ends.
z
When the space remaining in the normal recording area 
drops below a preset value, the FULL indicator on the 
digital video recorder’s front panel starts to flash. If 
recording is continued beyond this point, the normal 
recording area will become full, recording will stop, and 
the FULL indicator will stop flashing and remain lit. In 
such a case, use the <RECORDING AREA SET> menu 
to perform “AREA FULL RESET” for the normal 
recording area, thus allowing recording to start again 
from the beginning. (JP.60)
z
Playback is possible even while recording. See P.22 for 
more details.
2
Press the [TIMER] button.
The TIMER indicator turns off and recording ends.
[REC/STOP] button
[TIMER] button
FULL indicator
POWER indicator
Normal recording
Ending normal recording
02
0
01-01-04 00:00:00 REC REPEAT EN A ALARM 0000
Recording symbol
REC/STOP
REC/STOP
Timer recording
Stopping timer recording before completion
02
0
01-01-04 00:00:00 REC REPEAT EN A ALARM 0000
TIMER
TIMER
e00_l8hbe_xe_7.book  Page 19  Tuesday, April 27, 2004  10:35 AM