Raritan Computer 255-30-6000-00 用户手册

下载
页码 239
 
Chapter 8: Firmware Upgrade 
 
 
161
 
 
Important: Do NOT interrupt the upgrade process. Otherwise it 
results in permanent damages.
 
3.  Stacking Unit automatically restarts itself after the update completes. 
¾
 
To verify the firmware version 
Use the Function Menu on the Front Panel to check the firmware version. 
See Paragon II Front Panel Display and Controls (on page 16) for more 
information. 
¾
 
To recover Stacking Units after upgrade failure 
If a Stacking Unit encounters the update failure, with its failsafe 
capability, you can restore the Stacking Unitʹs function by yourself. 
1.  Make sure only one Stacking Unit (the one that encounters the update 
failure) is connected to the Main Unit. If not, see STEP 2 in the 
previous section ʺUpdating Stacking Units for Failsafe Upgrade 
Feature
ʺ for instructions. 
2.  Check the Front Panel LCD display on the Stacking Unit to see 
whether it enters the boot loader mode as shown below: 
 
If not, press and hold FUNC and ESC on the Front Panel of the 
Stacking Unit simultaneously, and power cycle the Stacking Unit at 
the same time. This forces it to enter the boot loader mode. 
3.  Follow the steps outlined in General Update Procedure (on page 153) 
to upgrade your Stacking Unit, but you must choose 
“R‐P2SBL‐0C5.hex” as the firmware file.