Generac 04675-3 Benutzerhandbuch

Seite von 59
  18 
4.3  CHANGING THE ENGINE OIL
4.3.1  ENGINE OIL RECOMMENDATIONS
Use oil of American Petroleum Institute (API) Service 
Class  SG,  SH  or  SJ.  Use  all  season  SAE  5W-30 
Synthetic oil. Organic break-in oil is required before 
using synthetic oil.
NOTE:
The  unit  is  supplied  with  “break-in”  oil.  See  the 
“Break-in  Procedure,”  Section  3.1,  for  the  first 
required oil change.
 
  Any attempt to crank or start the engine before 
it has been properly serviced with the recom-
mended oil may result in an engine failure.
4.3.2  OIL CHANGE PROCEDURE
To change the oil, proceed as follows:
1.  Run the engine until it is thoroughly warmed up 
then shut OFF the engine.
2.  Immediately after the engine shuts OFF, pull the 
oil  drain  hose  (Figure  4.4)  free  of  its  retaining 
clip. Remove the cap from the hose and drain the 
oil into a suitable container.
Figure 4.4 – Oil Drain Hose and Filter
Oil Filter
Oil
Drain
Hose
Loosen
3.  After the oil has drained, replace the cap onto the 
end  of  the  oil  drain  hose.  Retain  the  hose  in  the 
clip.
4.  Refill  with  the  proper  recommended  oil  (see 
Section  4.3.1).  See  Section  1.5.2  for  oil  capaci-
ties.
4.4  CHANGING THE OIL FILTER
Change the engine oil filter as follows:
1.  With the oil drained, remove the old oil filter by 
turning it counterclockwise.
2.  Apply  a  light  coating  of  clean  engine  oil  to  the 
gasket of the new filter. See Section 1.5.1 for rec-
ommended filter.
3.  Screw  the  new  filter  on  by  hand  until  its  gasket 
lightly contacts the oil filter adapter. Then, tighten 
the  filter  an  additional  3/4  to  one  turn  (Figure 
4.4).
4.  Refill  with  the  proper  recommended  oil  (see 
Section  4.3.1).  See  Section  1.5.2  for  oil  capaci-
ties.
5.  Start the engine and check for leaks.
4.5   CHANGING THE ENGINE 
AIR CLEANER
4.5.1   7 KW, 12 KW AND 15 KW 
GENERATORS
See  Figures  1.1  and  1.2,  for  the  location  of  the  air 
cleaner. Use the following procedure (Figure 4.6):
1.  Turn the two screws counterclockwise to loosen.
2.  Remove the cover and air filter.
3.  Wipe away dust or debris from inside of the air 
box and around edges.
4.  Install the new air cleaner into the air box.
5.  Install the cover. Turn the two cover screws clock-
wise to tighten.
See  the  “Service  Schedule,”  Section  4.13  for  air 
cleaner maintenance. See Section 1.5.1 for air filter 
replacement part number.
Figure 4.6 — 7 kW, Engine Air Cleaner Location
Air Cleaner
Fuel
Regulator
3/4" Hole
Section 4 — Maintenance
Air-cooled 7 kW, 12 kW and 15 kW Generators