Figure 4.7 — 12 kW and 15 kW Engine
Air Cleaner
Cover
Filter
Screw
4.6  SPARK PLUG(S)
Reset  the  spark  plug(s)  gap  or  replace  the  spark 
plug(s)  as  necessary.  See  Section  4.13  for  mainte-
nance requirements.
1.  Clean  the  area  around  the  base  of  the  spark 
plug(s) to keep dirt and debris out of the engine. 
Clean by scraping or washing using a wire brush 
and commercial solvent. Do not blast the spark 
plug(s) to clean.
2.  Remove  the  spark  plug(s)  and  check  the  condi-
tion. Replace the spark plug(s) if worn or if reuse 
is questionable. See Section 4.13 for recommend-
ed inspection.
3.  Check  the  spark  plug  gap  using  a  wire  feeler 
gauge.  Adjust  the  gap  to  0.76  mm  (0.030  inch) 
for 7 kW and 0.50 mm (0.020 inch) for 12/15 kW 
by carefully bending the ground electrode (Figure 
4.8).
Figure 4.8 – Setting the Spark Plug Gap
4.7  BATTERY MAINTENANCE
The  battery  should  be  inspected  per  the  “Service 
Schedule,”  Section  4.13.  The  following  procedure 
should be followed for inspection:
1.  Inspect the battery posts and cables for tightness 
and corrosion. Tighten and clean as necessary.
2.  Check the battery fluid level of unsealed batteries 
and,  if  necessary,  fill  with  DISTILLED  WATER 
ONLY.  DO  NOT  USE  TAP  WATER  IN  BATTER-
IES.
3.  Have the state of charge and condition checked. 
This should be done with an automotive-type bat-
tery hydrometer. 
DANGER
  Do not dispose of the battery in a fire. The 
battery is capable of exploding.
  A battery presents a risk of electrical shock 
and high short circuit current. The following pre-
cautions are to be observed when working on 
batteries:
•  Remove watches, rings or other metal objects;
• Use tools with insulated handles;
• Wear rubber gloves and boots;
•  Do not lay tools or metal parts on top of the 
battery; and
•  Disconnect charging source prior to connecting or 
disconnecting battery terminals.
  Do not open or mutilate the battery. Released 
electrolyte has been known to be harmful to the 
skin and eyes, and to be toxic.
  The electrolyte is a dilute sulfuric acid that is 
harmful to the skin and eyes. It is electrically 
conductive and corrosive. The following 
procedures are to be observed:
• Wear full eye protection and protective clothing;
•  Where electrolyte contacts the skin, wash it off 
immediately with water;
•  Where electrolyte contacts the eyes,  immediately 
flush thoroughly with water and seek medical 
attention; and
•  Spilled electrolyte is to be washed down with an 
acid neutralizing agent. A common practice is to 
use a solution of 1 pound (500 grams) bicarbonate 
of soda to 1 gallon (4 liters) or water. The bicar-
bonate of soda solution is to be added until the 
evidence of reaction (foaming) has ceased. The 
resulting liquid is to be flushed with water and the 
area dried.
  Lead-acid batteries present a risk of fire because 
they generate hydrogen gas. The 
Section 4 — Maintenance
Air-cooled 7 kW, 12 kW and 15 kW Generators
SET PLUG GAP AT 0.76 mm/0.50 mm
(0.030 inch/0.020 inch)