LOCATION REQUIREMENTS
You will need:
 
A location allowing for proper exhaust installation.  
See “Venting Requirements.”
 
A separate 15 or 20-amp circuit needed for gas dryers and 
30-amp circuit needed for electric dryers.
 
If using power supply cord, a grounded electrical outlet  
located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”
 
Floor must support dryer weight of 200 lbs. (90.7 kg).  
Also consider weight of companion appliance.
 
Level floor with maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), clothes may not 
tumble properly and automatic sensor cycles may not 
operate correctly.
 
For garage installation, place dryer at least 18" (460 mm) 
above floor. 
 
Steam models only: Cold water faucets located within 4 ft. 
(1.2 m) of the water fill valves, and water pressure of 20-100 
psi (137.9-689.6 kPa). You may use the water supply for your 
washer using the “Y” connector provided.
Do not operate your dryer at temperatures below 45° F (7°C). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic sensor cycle. this can result in longer drying times.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check codes requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the 
same closet as a dryer.
DRYER DIMENSIONS
INSTALLATION CLEARANCES
The location must be large enough to allow the dryer door  
to open fully.
NOTE: Most installations require a minimum of 5" (127 mm) 
clearance behind dryer for exhaust vent with elbow. See “Venting 
Requirements.”
Back view:
Bottom view:
Side view with open door dimensions: