GAS DRYER POWER HOOKUP
ELECTRICAL REQUIREMENTS
 
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is also recommended that a separate 
circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment- 
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases 
with appropriate conversion.
 
Your dryer must have the correct burner for the type of gas 
in your home. Burner information is located on the rating 
plate in the door well of your dryer. If this information does 
not agree with the type of gas available, contact your dealer 
or call the phone numbers referenced in the “Assistance or 
Service” section of your “Use and Care Guide.”
GAS SUPPLY REQUIREMENTS