Mitsubishi Electronics 60/60S User Manual
4. Parameters (User)
4.2 Machining Parameters
I-152
<Deep hole drilling cycle>
# Item
Contents
Setup
range
(unit)
8083 G83S modeM
(for M system only)
Set the M command code for changing to the small
diameter deep hole drilling cycle mode.
diameter deep hole drilling cycle mode.
1 to 99999999
8084 G83S Clearanse
(for M system only)
Set the clearance amount for the G83 small
diameter deep hole drilling cycle.
diameter deep hole drilling cycle.
0 to 999.999 (mm)
8085 G83S Forward F
(for M system only)
Set the feedrate from the R point to the cutting start
position in the G83 small diameter deep hole drilling
cycle.
position in the G83 small diameter deep hole drilling
cycle.
0 to 99999 (mm/min)
8086 G83S Back F
(for M system only)
Set the speed for returning from the hole base
during the G83 small diameter deep hole drilling
cycle.
during the G83 small diameter deep hole drilling
cycle.
0 to 99999 (mm/min)
<SSS control>
# Item
Contents
Setup
range
(unit)
8090 SSS ON
(for M system only)
Set whether to validate SSS control with G05
P10000.
P10000.
0: Invalid
1: Valid
1: Valid
0/1
8091 StdLength
(for M system only)
Adjust the maximum value of the range for
recognizing the shape.
To eliminate the effect of steps or errors, etc., set a
large value. To enable sufficient deceleration, set a
small value.
If "0.000" is set, the standard value (1.000mm) will
be applied.
recognizing the shape.
To eliminate the effect of steps or errors, etc., set a
large value. To enable sufficient deceleration, set a
small value.
If "0.000" is set, the standard value (1.000mm) will
be applied.
0 to 100.000 (mm)
8092 ClampCoeff
(for M system only)
Adjust the clamp speed at the curved section
configured of fine segments.
configured of fine segments.
Coefficient =
setting value
1 to 100
8093 StepLeng
(for M system only)
Set the width of the step at which the speed is not to
be decelerated. (Approximately the same as the
CAM path difference [Tolerance].)
If 0 is set, the standard value (5µm) will be applied.
If a minus value is set, the speed will decelerate at
all minute steps.
be decelerated. (Approximately the same as the
CAM path difference [Tolerance].)
If 0 is set, the standard value (5µm) will be applied.
If a minus value is set, the speed will decelerate at
all minute steps.
-0.001 to 0.100 (mm)
8094 DccWaitAdd
(for M system only)
Set the time to wait for deceleration when the speed
FB does not drop to the clamp speed.
FB does not drop to the clamp speed.
0 to 100 (ms)
8095 Tolerance
(for M system only)
Set the tolerable error when the error between the
command path and tool path is large.
The error will decrease when a small value is set,
but the machining time will increase.
If "0.000" is set, the error will not be adjusted.
command path and tool path is large.
The error will decrease when a small value is set,
but the machining time will increase.
If "0.000" is set, the error will not be adjusted.
0 to 100.000 (mm)