4. Parameters (User)
4.2 Machining Parameters
I-153
4.2.2 Control Parameters
[CONTROL PARAMETER]
PARAM 1.5/8
#
#
8101 MACRO SINGLE
0
8113 MillingInitG16
8102 COLL. ALM OFF
0
8114 MillingInitG19
8103 COLL. CHK OFF
0
8115
8104
8116
8105 EDIT LOCK B
0
8117
8106 G46 NO REV-ERR
0
8118
8107 R COMPENSATION
0
8119
8108 R COMP Select
0
8120
8109 HOST LINK
0
8121
8110 G71/G72 POCKET
0
8122
8111 Milling Radius
0
8123
8112 DECIMAL PNT-P
0
8124
# ( ) DATA( )
WORK
PROCESS
I/O PAR
SETUP
MENU
# Item
Contents
Setup
range
(unit)
8101 MACRO SINGLE
Select the control of the blocks where the user
macro command continues.
macro command continues.
0: Do not stop while macro block continues.
1: Stop every block during signal block
1: Stop every block during signal block
operation.
0/1
8102 COLL. ALM OFF
Select the interference (bite) control to the
workpiece from the tool diameter during tool radius
compensation and nose R compensation.
workpiece from the tool diameter during tool radius
compensation and nose R compensation.
0: An alarm is output and operation stops when
an interference is judged.
1: Changes the path to avoid interference.
0/1
8103 COLL. CHK OFF
Select the interference (bite) control to the
workpiece from the tool diameter during tool radius
compensation and nose R compensation.
workpiece from the tool diameter during tool radius
compensation and nose R compensation.
0: Performs interference check.
1: Does not perform interference check.
1: Does not perform interference check.
0/1
8105 EDIT LOCK B
Select the edit lock for program Nos. 8000 to 9999.
0: Program can be edited.
1: Editing of above program is prohibited.
1: Editing of above program is prohibited.
0/1
8106 G46 NO REV-ERR
(For L system only)
Select the control for the compensation direction
reversal in G46 (nose R compensation).
reversal in G46 (nose R compensation).
0: An alarm is output and operation stops when
the compensation direction is reversed (G41
→ G42‚ G42 → G41).
→ G42‚ G42 → G41).
1: An alarm does not occur when the
compensation direction is reversed‚ and the
current compensation direction is maintained.
current compensation direction is maintained.
0/1