INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read 
and follow the instructions provided with any tools listed here. 
Flat-blade screwdriver
Adjustable wrench that 
opens to 1" (25 mm) or 
 
hex-head socket wrench 
 
(for adjusting dryer feet)
Level
Vent clamps
Knife
Caulking gun and compound 
(for installing new exhaust 
vent)
Tin snips (new vent 
installations)
1/4" nut driver 
(recommended)
Tape measure
Pliers
For All Installations:
Gas Installations:
8" or 10" pipe wrench
8" or 10" adjustable wrench 
(for gas connections)
Pipe-joint compound 
resistant to LP gas
Parts supplied
Non-Steam Models
4 Leveling legs
Steam Models
A
B
C
D
E
A. Leveling legs (4)
B. “Y” connector
C. Short inlet hose
D. Inlet hose with right-angle 
connector
E. Rubber washer
Remove parts package from dryer drum. Check that all parts 
 
are included.
NOTE: Do not use leveling legs supplied with dryer if installing 
 
on a pedestal.
Parts needed
Check local codes. Check existing electrical supply and venting. 
See “Electrical Requirements” and “Venting Requirements” before 
purchasing parts.
Mobile home installations require metal exhaust system hardware 
available for purchase from the dealer from whom you purchased 
your dryer. For further information, please refer to the “Assistance 
 
or Service” section in your Use and Care Guide.
Optional Equipment
Refer to your Use and Care guide for information about the 
accessories available for your dryer.
Location Requirements 
You will need
A location that allows for proper exhaust installation. 
 
See “Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical 
outlet located within 2 ft. (610 mm) of either side of the dryer. 
 
See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs 
 
(90.7 kg). The combined weight of a companion appliance 
should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), install Extended Dryer 
Feet Kit, Part Number 279810. Clothes may not tumble properly 
and automatic sensor cycles may not operate correctly if dryer 
 
is not level.
For a garage installation, you will need to place the dryer at least 
18" (460 mm) above the floor. If using a pedestal, you will need 
18" (460 mm) to the bottom of the dryer.
Steam models only: Cold water faucets located within 
 
4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi 
 
(137.9-689.6 kPa). Cold water supply may come from 
 
washer using “Y” connector provided.
Do not operate your dryer at temperatures below 45ºF (7ºC). 
 
At lower temperatures, the dryer might not shut off at the end 
 
of an automatic sensor cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will 
 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, 
 
or sleeping quarters. Contact your local building inspector.