Optional exhaust installations.
Exhaust Cover Kit (to cover unused exhaust holes):
Part Number W10186596 - all models
This dryer can be converted to exhaust out the right side, left side 
 
or through the bottom. If you prefer, you may contact your local 
dealer to have the dryer converted.
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best 
 
for your installation. Two close-clearance installations are shown. 
Refer to the manufacturer’s instructions. 
               A                                   B
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate installations 
are available for purchase. Please see the “Assistance or Service” 
section in your Use and Care Guide to order.
Over-the-Top Installation: 
 
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent 
mismatch):
 
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) 
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct 
path outdoors. 
Plan the installation to use the fewest number of elbows 
 
and turns. 
When using elbows or making turns, allow as much room 
 
as possible. 
Bend vent gradually to avoid kinking. 
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best 
drying performance
Use the following vent system chart to determine type of vent 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified 
 
in the Vent system chart. 
Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times 
 
and increased energy usage.
The vent system chart provides venting requirements that will help 
to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn inside 
the dryer. To determine maximum exhaust length, add one 90º turn 
to the chart.
Number 
 
90º elbows
Type of vent
Box /Louvered 
 
hoods
Angled 
hoods
0
Rigid metal
64 ft. (20 m)
58ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m) 
48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)