Intel E3815 FH8065301567411 Data Sheet

Product codes
FH8065301567411
Page of 5308
Intel
®
 Atom™ Processor E3800 Product Family
1120
Datasheet
30
0h
RO
SP_STR_MON_PIFB2SP_valid: 
Returns the value 1 if a valid acknowledge token from 
the FIFO between the primary input formatter B acknowledge port and the SP, is present 
on the primary input formatter B input port of the SP. Returns the value 0 if there is no 
valid acknowledge token available on this SP input port.
29
0h
RO
SP_STR_MON_SP2PIFB_accept: 
Returns the value 1 if the command FIFO between 
SP and the Primary input formatter B can accept a command from the SP. Returns the 
value 0 if this FIFO cannot accept a token from the SP.
28
0h
RO
SP_STR_MON_SP2PIFB_valid: 
Returns the value 1 if SP sends a command using the 
streaming port connected to the Primary Input Formatter B command FIFO. Returns the 
value 0 if the SP does not send a command to this FIFO
27
0h
RO
SP_STR_MON_PIF2SP_accept: 
Returns the value 1 if the SP can accept an 
acknowledge token from the FIFO between the primary input formatter acknowledge 
port and the SP. Returns the value 0 if the SP cannot accept a token on this SP input 
port.
26
0h
RO
SP_STR_MON_PIF2SP_valid: 
Returns the value 1 if a valid acknowledge token from 
the FIFO between the primary input formatter acknowledge port and the SP, is present 
on the primary input formatter input port of the SP. Returns the value 0 if there is no 
valid acknowledge token available on this SP input port.
25
0h
RO
SP_STR_MON_SP2PIF_accept: 
Returns the value 1 if the command FIFO between SP 
and the Primary input formatter can accept a command from the SP. Returns the value 0 
if this command FIFO cannot accept a command from the SP.
24
0h
RO
SP_STR_MON_SP2PIF_valid: 
Returns the value 1 if SP sends a command using the 
streaming port connected to the Primary Input Formatter command FIFO. Returns the 
value 0 if the SP does not send a command to the Primary Input formatter
23
0h
RO
SP_STR_MON_ISYS2SP_accept: 
Returns the value 1 if the SP can accept an 
acknowledge token from the FIFO between the input system acknowledge port and the 
SP. Returns the value 0 if the SP cannot accept a token on this SP input port.
22
0h
RO
SP_STR_MON_ISYS2SP_valid: 
Returns the value 1 if a valid acknowledge token from 
the FIFO between the input system acknowledge port and the SP, is present on the input 
system input port of the SP. Returns the value 0 if there is no valid acknowledge token 
available on this SP input port.
21
0h
RO
SP_STR_MON_SP2ISYS_accept: 
Returns the value 1 if the command FIFO between 
SP and the input system can accept a command from the SP. Returns the value 0 if this 
command FIFO cannot accept a command from the SP.
20
0h
RO
SP_STR_MON_SP2ISYS_valid: 
Returns the value 1 if SP sends a command using the 
streaming port connected to the input system command FIFO. Returns the value 0 if the 
SP does not send a command to the input system
19
0h
RO
SP_STR_MON_GPD2SP_accept: 
Returns the value 1 if the SP can accept a token 
from the streaming FIFO between the fifo adpater in GP devices and the SP. Returns 0 if 
the SP cannot accept a token from this FIFO.
18
0h
RO
SP_STR_MON_GPD2SP_valid: 
Returns the value 1 if the streaming FIFO between the 
fifo adapter in GP devices and the SP has a valid token for the SP. Returns the value 0 if 
this FIFO is empty.
17
1h
RO
SP_STR_MON_SP2GPD_accept: 
Returns the value 1 if the token FIFO between SP 
and fifo adapter can accept a token from the SP. Returns the value 0 if this token FIFO is 
full.
16
0h
RO
SP_STR_MON_SP2GPD_valid: 
Returns the value 1 if SP sends a token using the 
streaming port connected to the token FIFO between the SP and the fifo adapter in 
GP_devices. Returns the value 0 if the SP does not send a token to the fifo adapter.
15
0h
RO
SP_STR_MON_ISP2SP_accept: 
Returns the value 1 if the SP can accept a token from 
the streaming FIFO between the ISP and the SP. Returns 0 if the SP cannot accept a 
token from this FIFO.
14
0h
RO
SP_STR_MON_ISP2SP_valid: 
Returns the value 1 if the streaming FIFO between the 
ISP and the SP has a valid token for the SP. Returns the value 0 if this FIFO is empty
13
1h
RO
SP_STR_MON_SP2ISP_accept: 
Returns the value 1 if the token FIFO between SP 
and ISP can accept a token from the SP. Returns the value 0 if this token FIFO is full.
Bit 
Range
Default & 
Access
Description