15.8.6
reg_gpd_gp_reg_reg_gp_sp_stream_stat_b_type 
(gpd_gp_reg_reg_gp_sp_stream_stat_b)—Offset 14h
Indicate the status of the streaming ports of the scalar processor. All valid and accept 
signals of the scalar processor are reflected in this register and in 
reg_gp_sp_stream_stat.
Access Method
12
0h
RO
SP_STR_MON_SP2ISP_valid: 
Returns the value 1 if SP sends a token using the 
streaming port connected to the ISP token FIFO. Returns the value 0 if the SP does not 
send a token to the ISP
11
0h
RO
SP_STR_MON_DMA2SP_accept: 
Returns the value 1 if the SP can accept an 
acknowledge token from the FIFO between the DMA acknowledge port and the SP. 
Returns the value 0 if the SP cannot accept a token on this SP input port.
10
0h
RO
SP_STR_MON_DMA2SP_valid: 
Returns the value 1 if a valid acknowledge token from 
the FIFO between the DMA acknowledge port and the SP, is present on the DMA input 
port of the SP. Returns the value 0 if there is no valid acknowledge token available on 
this SP input port.
9
0h
RO
SP_STR_MON_SP2DMA_accept: 
Returns the value 1 if the command FIFO between 
SP and the DMA can accept a command from the SP. Returns the value 0 if this 
command FIFO cannot accept a command from the SP.
8
0h
RO
SP_STR_MON_SP2DMA_valid: 
Returns the value 1 if SP sends a command using the 
streaming port connected to the DMA command FIFO. Returns the value 0 if the SP does 
not send a command to the DMA
7
0h
RO
SP_STR_MON_MC2SP_accept: 
Returns the value 1 if the SP can accept an 
acknowledge token from the FIFO between the stream2mem acknowledge port and the 
SP. Returns the value 0 if the SP cannot accept a token on this SP input port.
6
0h
RO
SP_STR_MON_MC2SP_valid: 
Returns the value 1 if a valid acknowledge token from 
the FIFO between the stream2mem acknowledge port and the SP, is present on the 
stream2mem input port of the SP. Returns the value 0 if there is no valid acknowledge 
token available on this SP input port.
5
1h
RO
SP_STR_MON_SP2MC_accept: 
Returns the value 1 if the command FIFO between SP 
and the stream2mem can accept a command from the SP. Returns the value 0 if this 
command FIFO is full.
4
0h
RO
SP_STR_MON_SP2MC_valid: 
Returns the value 1 if SP sends a command using the 
streaming port connected to the stream2mem command FIFO. Returns the value 0 if the 
SP does not send a command to the stream2mem
3
0h
RO
SP_STR_MON_SIF2SP_accept: 
Returns the value 1 if the SP can accept an 
acknowledge token from the FIFO between the secondary input formatter acknowledge 
port and the SP. Returns the value 0 if the SP cannot accept a token on this SP input 
port.
2
0h
RO
SP_STR_MON_SIF2SP_valid: 
Returns the value 1 if a valid acknowledge token from 
the FIFO between the secondary input formatter acknowledge port and the SP, is 
present on the secondary input formatter input port of the SP. Returns the value 0 if 
there is no valid acknowledge token available on this SP input port.
1
1h
RO
SP_STR_MON_SP2SIF_accept: 
Returns the value 1 if the command FIFO between SP 
and the secondary input formatter can accept a command from the SP. Returns the 
value 0 if this command FIFO is full.
0
0h
RO
SP_STR_MON_SP2SIF_valid: 
Returns the value 1 if SP sends a command using the 
streaming port connected to the Secondary Input Formatter command FIFO. Returns 
the value 0 if the SP does not send a command to the Secondary Input formatter
Bit 
Range
Default & 
Access
Description